Electric Process For Heaters Natural Gas Pressure Reduction Station

Brand Name : MICH

Model Number : MICHNGMPRS

Certification : ISO9001

Place of Origin : China

MOQ : 1 piece

Price : USD20-USD200,000

Supply Ability : As per the product output capacity

Delivery Time : in one month

Packaging Details : plywood crates

Heating Element : mineral insulated heating cable

Media : Natural gas

Property : Explosion-proof

Application : Metering or Pressure Reduction

Explosion-proof rating : dIIB T1-T6

Function : Heat Compensating

Style : Vertical or Horizontal

Pressure : UP to 12-25 MPa

Contact Now

MI Cable Heater for Natural Gas Metering or Pressure Reduction Station produced by MICH, optimize equipment functionality and provide protection against cooling & condensate. The customized designed heaters can be installed wherever pressure reduction leads to temperature drop and condensation. This includes sampling & test outlets at metering stations, as well as pipeline pressure reduction stations. MI Heaters are also effective in heating pilot tube gas streams, which may run throughout a system to maintain warmth, preventing the formation of damaging frost or condensation on valves, seals, and small components.
With MI Heaters, all heated media is isolated in seamless stainless steel flow-tubes: gases have no contact with heating elements or any other components within the heater. This is an important safety feature, enabling the MI Cable Heater design to heat flammable and explosive media.
The Heaters are compatible with continuous high-pressure operation.

Explosion-proof electric enclosures (NEMA 7 and ATEX) are standard options.
Available from .5 up to 60 kW, the MI cable Heaters can be configured to meet any worldwide voltage.
Heaters are easily integrated and use standard fittings and controls (PID, PLC, etc.).

Technical Properties

1. The gas electric heater uses mineral insulated (MI) heating cable as heating element to transfer heat to the heat exchange chamber via a heat medium. The heat between the heated medium and the heating element are indirectly transmitted.

2. The heated gas is guided to flow along the sparger in the heat exchange chamber, and has a good flow heat exchange effect.

3. A temperature sensor being set at the outlet of the heat exchange chamber, the temperature automatic control can be realized after being connected with the matched temperature control cabinet.

4. The conventional pressure grade of 0.6~12MPa can be designed and produced, and higher pressure (12~25MPa) grade can also be done for professional users.

5. In explosion-proof locations, device connections and electrical wiring are in compliance with explosion-proof specifications with an explosion-proof rating dIIB T1-T6.

Working Principle

The cold medium enters the heat exchange chamber via the inlet pipe, guides the tortuous turbulence along the baffle plate, and flows to the outlet pipe at a uniform temperature after a predetermined heat exchange process. A temperature sensor being installed in the outlet pipe of the heat exchange chamber and the temperature signal being collected and transmitted to the electrical control system, the primary circuit electrical component is controlled by the temperature regulator to realize automatic temperature control. At the same time, it is equipped with a flow lockout device to stop automatically the power output of the electric heating element when the medium flow is relatively small while to resume the normal heating by increasing the flow rate immediately and an over-temperature protection device is provided.

Parameter and Specification

1.Model Meaning

Electric Process For Heaters Natural Gas Pressure Reduction StationElectric Process For Heaters Natural Gas Pressure Reduction StationElectric Process For Heaters Natural Gas Pressure Reduction Station

Electric Process For Heaters Natural Gas Pressure Reduction Station Gas explosion-proof electric heater

2.Main engineering data

Electric Process For Heaters Natural Gas Pressure Reduction Station

Gas electric heater outline drawing

Table 1: QJRQ Parameter and Size of Vertical Gas Electric Heater

Model Rated power Kw Rated voltage (V) Rated current (A) NO of power phases Dimensions(mm) Equipment Weight(Kg)
h1 h2 H D

6.3

MPa

4.0

MPa

2.5

MPa

QJRQ-3/220 3 220 13.5 1 600 580 1750 φ273 300 235 200
QJRQ-6/220 6 220 22.5 1 600 960 2000 φ273 320 260 220
QJRQ-9/3/380 9 380 13.7 3 600 1300 2400 φ273 350 280 240
QJRQ-12/3/380 12 380 18 3 600 1600 2700 φ273 400 330 290
QJRQ-15/3/380 15 380 22.7 3 630 825 2200 φ377 420 360 320
QJRQ-24/3/380 24 380 36 3 630 1500 2828 φ377 620 530 480
QJRQ-36/3/380 36 380 54.5 3 630 2430 3728 φ377 826 760 703
QJRQ-60/3/380 60 380 91 3 835 0 3815 φ550 2000 1770 1560
QJRQ-81/3/380 81 380 123 3 835 0 4415 φ550 2300 1920 1680
QJRQ-102/3/380 102 380 150 3 905 0 3965 φ700 3010 2550 2050
QJRQ-150/3/380 150 380 226 3 905 0 4570 φ700 3450 2850 2185
QJRQ-200/3/380 200 380 303 3 905 0 5370 φ700 3960 3050 2300
QJRQ-300/3/380 300 380 456 3 1076 0 5616 φ1000 8000 6500 4300
QJRQ-400/3/380 400 380 608 3 1106 0 6446 φ1000 9440 7250 5100


Product Tags:

mi Electric Process Heaters

      

380v electric process heaters

      

25 MPa mi heater

      
Quality Electric Process For Heaters Natural Gas Pressure Reduction Station for sale

Electric Process For Heaters Natural Gas Pressure Reduction Station Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Pasia Industries Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)